@ -0,0 +1,21 @@
# MQTT Configuration
## Rules
When configuring MQTT in a camera or other device, these rules need to be respected due to assumptions made in how we process and route messages.
### Connection messages
Currently we receive connect, but not disconnect messages. AppMqtt does receive a disconnect, but it is not converted and sent in the pipeline today. These standards presume that the disconnected message can be added one day.
- Topics end with "/event/connection".
- Payload has a boolean `connected` showing the connection state.
- Payload has a `description` of the event of "Connected" or "Disconnected".
### Application event messages
For axis cameras, these events come from the ACAP applications.
- Payload contains `topic`, with 3 parts delimited by "/". The 2nd part is the application name. E.g., "VMD". The 3rd part is the profile identifier (aka "zone"). E.g., "Camera1ProfileANY" indicates any zone.
- Payload contains `message` object, which contains `data`. For zone triggering, `data` contains `active`, with a string value of "1" or "0".